SA-D-HV_img_01psd.png
SCHOOLAIR-D-HV
SA-D-HV_img_01psd.png
SCHOOLAIR-B_img_11psd.png
Copy_of_VDI6022_gs_01ai.png
SA-D-HV_img_12psd.png

X-CUBE SCHOOLAIR-D-HV     

Supply and extract air unit with switchover option for secondary air operation, including rotary heat recovery unit and heat exchanger for installation below the ceiling

Ready-to-operate decentralised ventilation unit that provides good comfort levels and is used for the ventilation of internal spaces such as classrooms or conference rooms and day nurseries

  • Freely suspended installation or partially or fully integrated in a suspended ceiling
  • Acoustically optimised EC fans with low specific fan power, SFP = 0 to EN 16798-3
  • Rotary heat recovery unit (75% heat recovery efficiency) with moisture recovery in winter
  • Highly efficient heat exchanger for heating as a 2-pipe system
  • Heat exchanger connection is on the right when seen from the room
  • Heat recovery all year round
  • Reduced fine dust and pollen contamination due to integral filters that conform to VDI 6022 – filter class ISO ePM1 60% and extract air ISO coarse 90%
  • Easy filter change, no tools required
  • Motorised shut-off dampers, normally closed (NC)
  • Installation without interruption of school operations


Optional equipment and accessories

  • Modular control system FSL-CONTROL III, specially for decentralised ventilation systems
  • With electric air heater

 

Functional description 

Functional description

Decentralised supply and extract air units ventilate the room and cover the heating load according to the technical data. An EC centrifugal fan takes in the outdoor air which then flows through the motorised shut-off damper and the outdoor air filter. The outdoor air then flows through the rotary heat recovery unit, which can be switched off in energy efficient operating situations. If necessary, the air is heated or cooled by the heat exchanger before it is draught-freely discharged to the room with momentum from the supply air grille near the ceiling (this is optional for change-over systems). 

The extract air first passes through the extract air filter, then flows through the heat recovery unit, the extract air fan and the motorised shut-off damper before it is discharged to the outside as exhaust air. If the indoor air quality is sufficient, FSL-CONTROL III closes the outdoor air dampers and changes to secondary air operation, which is more energy efficient in any case. The control system compares the room air quality setpoint value to the actual value measured by the COsensor and switches automatically between outdoor air and secondary air operation.

In case of a power failure, the outdoor air and exhaust air dampers are closed to ensure fire protection, frost protection and to avoid draughts. This is ensured by a capacitor in each actuator.

The supply air is discharged near the ceiling with a medium velocity. The Coanda effect causes the beam to be deflected upwards. Rather than flowing immediately downwards, the air moves along the ceiling (Coanda effect) and reaches every corner; this ensures complete ventilation even of large rooms. Once the air reaches the opposite wall, it moves downwards and eventually through the entire space. The airflow reaching the occupied zone has a very low velocity and rises on heat sources, for example on people and devices. This is called natural convection. As a result, the air is exchanged primarily in these areas. The stale air is extracted under the ceiling and led to the outside.


Technical information

Function, Technical data, Quick sizing, Specification text, Order code

  • FUNCTION – SCHEMATIC ILLUSTRATION
  • TECHNICAL DATA
  • QUICK SIZING
  • SPECIFICATION TEXT
  • ORDER CODE

Variants, Product details

  • VARIANTS
  • PRODUCT DETAILS


Downloads

product information

certificates

operation manuals

production {"x-frame-options"=>"SAMEORIGIN", "x-xss-protection"=>"1; mode=block", "x-content-type-options"=>"nosniff", "x-download-options"=>"noopen", "x-permitted-cross-domain-policies"=>"none", "referrer-policy"=>"strict-origin-when-cross-origin", "strict-transport-security"=>"max-age=31536000; includeSubDomains", "content-type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Contact

We are here for you

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265