KSFS_img_02psd.png
KSFS-PM

  • Variant KSFS-PM: Casing with prefilter

KSFS_img_04psd.png

With sealing integrity test facility

KSFS_img_01psd.png

Optional double-groove service board

Explosion-proof construction optional
KSFS_img_02psd.png
KSFS_img_04psd.png
KSFS_img_01psd.png

KSFS

Fitting of filter elements for the separation of suspended particles in areas with critical requirements

Ducted particulate filter for Mini Pleat filter panels, Mini Pleat filter cells, and activated carbon filter cells. For installation into the ductwork of ventilation systems. Used in medicine, biology, the pharmaceuticals industry, and sensitive technical areas.

  • Ducted particulate filter made of sheet steel with decontaminable powder coating RAL 9010 and clamping mechanism made of stainless steel

  • Robust, welded construction with doubled-edged perimeter flanges with pre-drilled holes ensures secure sealing

  • One-stage or two-stage casing, for the fitting of fine dust filters as prefilter stage and of particulate filters as second filter stage

  • Secure sealing and convenient handling due to tensioning lever for a consistent contact pressure and hence sealing integrity between the casing and filter element

  • With sealing integrity test facility for filter elements

 


Optional equipment and accessories

  • Optional double-groove service board for contamination-free filter change ('safe change')

  • Plastic service bag with O-ring for contamination-free filter change

  • Explosion-proof construction for protection zones 1 and 2, as well as 21 and 22

 


 


 

General information

Application

  • Ducted particulate filters for critical requirements

  • Casing for duct installation

  • Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply or extract air.

  • Fitting of activated carbon filter cells for the separation of gaseous odorous substances and contaminants from the supply and extract air



Nominal sizes

  • B × H × T [mm]


Variants

  • M: Casing without prefilter

  • PM: Casing with prefilter



Construction

  • SPC steel, powder-coated RAL 9010 (pure white)

  • SPC-Ex steel, powder-coated RAL 9010 (pure white) in explosion-proof construction

  • STA stainless steel

  • STA-Ex stainless steel in explosion-proof construction


Options

  • MD: Casing with double-groove service board



Accessories

  • Plastic service bag with O-ring



Useful additions

  • Suitable filter elements to be ordered separately

  • Mini Pleat filter panels (MFP)

  • Mini Pleat filter cells (MFC)

  • Activated carbon filter cells (ACF)

  • Other filter elements upon request

  • Spigot (KSFSSP)



Construction features

  • Casing with robust, doubled-edged connecting flanges with pre-drilled holes.

  • Automatically adjusting clamping mechanism which guarantees sealing integrity between the casing and the filter element; this clamping mechanism can only be closed when the filter element is properly seated

  • Cover plate with profiled seal and 4 clamping screws with star grips

  • Prefilter casing for fitting Mini Pleat filter panels as fine dust filters

  • Double-groove service board and plastic service bag for contamination-free filter change

  • Sealing integrity test facility for Mini Pleat filter panels as particulate filters

  • Casing with indentations to ensure the precise fitting of the filter elements

  • Leakage classes D according to EN 15727 and L1 according to EN 1886

  • Leakage test for each individual casing



Materials and surfaces

  • Casing made of sheet steel, powder-coated RAL 9010, pure white, or of stainless steel

  • Stainless steel clamping mechanism



Installation and commissioning

  • Installation orientation: horizontal or vertical (rotated by 90°)

  • Pressure measurement points for each filter unit are part of the supply package but must be set up on site by others



Standards and guidelines

  • EN 15727; Ventilation for buildings – Ducts and ductwork components, leakage classification and testing

  • EN 1886; Ventilation for buildings – Air handling units – Mechanical performance

  • ATEX Directive 2014/34/EU



Maintenance

  • Filter change: Ejection mechanism for the easy removal of the filter elements from the filter casing


Technical information

Function, Specification text, Order code

  • FUNCTION
  • SPECIFICATION TEXT
  • ORDER CODE
Schematic illustration of KSFS
① Double-groove service board (optional)
② Sealing integrity test facility
③ Spigot for sealing integrity test facility
④ Ejection mechanism for filter change
⑤ Clamping mechanism for the filter element

Specification text

Ducted particulate filters KSFS for critical requirements as filter casings for installation into the ductwork of ventilation systems. Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply or extract air; also for the fitting of activated carbon filter cells for the adsorption of gaseous odorous substances and contaminants. Filter casings are available as one-stage construction or two-stage construction for the fitting of fine dust filters as prefilter stage and of particulate filters as second filter stage. Ducted particulate filter KSFS with robust, doubled-edged connecting flanges with pre-drilled holes. Clamping mechanism made of stainless steel with tensioning lever for uniform sealing integrity between the casing and filter element. Filter casing with sealing integrity test facility, available with optional double-groove service board and plastic service bag for contamination-free filter change. The cover plate is fitted with a profiled seal and 4 clamping screws with star grips. Pressure measurement points are part of the supply package but must be set up on site by others. Leakage classes D according to EN 15727 and L1 according to EN 1886. Leakage test for every casing. Optional: Filter casing KSFS with explosion protection, use in areas with a potentially explosive atmosphere of zones 1 and 2, as well as zones 21 and 22 (Ex II 2G Ex IIC T6 Gb and Ex II 2D Ex IIIB T80 °C Db). The filter casings must be connected to the earth potential. All conductive and dissipative parts must be connected together and grounded. Conductive dusts are excluded from the application. Under no circumstances should metallic foreign materials enter the filter casing.




Materials and surfaces

  • Casing made of sheet steel, powder-coated RAL 9010, pure white, or of stainless steel

  • Stainless steel clamping mechanism



Construction

  • SPC steel, powder-coated RAL 9010 (pure white)

  • SPC-Ex steel, powder-coated RAL 9010 (pure white) in explosion-proof construction

  • STA stainless steel

  • STA-Ex stainless steel in explosion-proof construction

KSFSPMSPC/710 × 794 × 710/MD
|||||
12345
1 Type
KSFS Duct particulate filter for high requirements
 
2 Variant
M Casing without prefilter
PM Casing with prefilter
 
3 Material
SPC steel, powder-coated RAL 9010 (pure white)
SPC-EX steel, powder-coated RAL 9010, pure white, in explosion-proof construction
STA stainless steel
STA-EX stainless steel in explosion-proof construction
 
4 Nominal size [mm]
B × H × T
 
5 Service board
No entry required: Without
MD casing with service board
   

Variants, Dimensions, Product details

  • VARIANTS
  • DIMENSIONS
  • PRODUCT DETAILS



Product specific data – KSFS-M

Nominal size

Filter size

~ Weight

B [mm]H [mm]T [mm]B × H × T [mm](kg)
710411405305 × 610 × 15040
710411710610 × 610 × 15050
710553405305 × 610 × 29255
710553710610 × 610 × 29265
710553862762 × 610 × 29270




Product specific data – KSFS-PM

Nominal size

Prefilter size

Main filter size

~ Weight

B [mm]H [mm]T [mm]B × H × T [mm](kg)
710652405305 × 610 × 60305 × 610 × 15060
710652710610 × 610 × 60610 × 610 × 15070
710794405305 × 610 × 60305 × 610 × 29270
710794710610 × 610 × 60610 × 610 × 29285
710794862762 × 610 × 60762 × 610 × 29295

Installation and commissioning

  • Observe the installation and maintenance manual

  • Installation orientation: horizontal or vertical (rotated by 90°)

  • Casing with indentations to ensure the precise fitting of the filter elements

  • Pressure measurement points for each filter unit are part of the supply package but must be set up on site by others

Downloads

product information

certificates

operation manuals

highlights

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Contact

We are here for you

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265