Application
Special characteristics
Nominal sizes
Parts and characteristics
Attachments
Accessories
Construction features
Materials and surfaces
Standards and guidelines
Maintenance
Functional description
Displacement flow diffusers discharge the air from air conditioning systems vertically and with a low velocity into the room, causing very little turbulence. This results in a very good air quality in the occupied zone.
Type QSH displacement flow diffusers are used primarily for industrial zones with air polluting work processes. They are installed preferably outside of occupied zones, e.g. high up in corridors. An adjustable air control disc allows for adapting the air discharge direction to heating or cooling mode. The supply air to room air temperature difference may range from –8 to +12 K.
Cooling mode
In cooling mode the supply air is discharged outside the occupied zone, from above and in a bell-shaped air pattern. This creates a pool of fresh air over the entire floor area, similar to displacement ventilation where the air is supplied near the floor. The convection from people and other heat sources causes the fresh air from the pool to rise and create comfortable conditions in the occupied zone.
Heating mode
In heating mode the air is discharged vertically.
The air control disc can be adjusted manually or with a thermal or electric actuator.
Extract air units should be installed in the upper part of a room, above the occupied zone.
Nominal sizes | 250, 355, 450, 560 mm |
Minimum volume flow rate | 205 – 785 l/s or 738 – 2826 m³/h |
Maximum volume flow rate, with LWA ≅ 55 dB(A) | 410 – 1570 l/s or 1476 – 5652 m³/h |
Supply air to room air temperature difference | –8 to +12 K |
Quick sizing tables provide a good overview of the volume flow rates and corresponding sound power levels and differential pressures.
The maximum volume flow rates apply to a sound power level of approx. 55 dB (A).
Sizing example
Given data
V = 500 l/s (1800 m3/h)
Displacement flow diffuser for installation in corridors
Maximum sound power level 50 dB(A)
Quick sizing
Type QSH
Nominal sizes: 355, 450
Selected: QSH/355
QSH supply air, horizontal air discharge, sound power level and total differential pressure
250 | 205 | 738 | 12 | 31 |
250 | 270 | 972 | 20 | 41 |
250 | 340 | 1224 | 32 | 48 |
250 | 410 | 1476 | 47 | 55 |
355 | 335 | 1206 | 11 | 34 |
355 | 435 | 1566 | 18 | 43 |
355 | 535 | 1926 | 27 | 50 |
355 | 635 | 2286 | 39 | 55 |
450 | 470 | 1692 | 9 | 27 |
450 | 625 | 2250 | 16 | 39 |
450 | 780 | 2808 | 25 | 48 |
450 | 940 | 3384 | 36 | 55 |
560 | 785 | 2826 | 14 | 29 |
560 | 1050 | 3780 | 25 | 40 |
560 | 1310 | 4716 | 39 | 49 |
560 | 1570 | 5662 | 56 | 55 |
QSH supply air, vertical air discharge, sound power level and total differential pressure
250 | 205 | 738 | 12 | 36 |
250 | 265 | 954 | 21 | 44 |
250 | 335 | 1206 | 33 | 51 |
250 | 385 | 1386 | 44 | 55 |
355 | 335 | 1206 | 11 | 38 |
355 | 420 | 1512 | 17 | 45 |
355 | 505 | 1818 | 25 | 51 |
355 | 590 | 2124 | 34 | 55 |
450 | 470 | 1692 | 10 | 33 |
450 | 595 | 2142 | 16 | 42 |
450 | 725 | 2610 | 24 | 49 |
450 | 855 | 3078 | 33 | 55 |
560 | 785 | 2826 | 15 | 36 |
560 | 990 | 3564 | 24 | 45 |
560 | 1180 | 4248 | 34 | 51 |
560 | 1370 | 4932 | 46 | 55 |
Displacement flow diffusers with a cylindrical casing, for industrial zones with air polluting work processes. With adjustable air control disc for air discharge from bell-shaped to vertical (90°). For free hanging installation and also for installation on walls or pillars, preferably outside the occupied zone, e.g. in corridors.
Ready-to-install component which consists of a cylindrical, perforated metal casing, air control disc and top entry spigot.
Spigot suitable for ducts to EN 1506 or EN 13180.
Sound power level of the air-regenerated noise measured according to EN ISO 5135.
Special characteristics
Materials and surfaces
Technical data
Sizing data
Air-regenerated noise
This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design programme.
Order example: QSH–E5/450/P1-RAL 9016
Actuator | 24 V AC/DC, 3-point |
Nominal size | 450 mm |
Fixing | Without |
Exposed surface | RAL 9016, traffic white, gloss level 70 % |
Installation and commissioning
These are only schematic diagrams to illustrate installation details.
Principal dimensions
ØD [mm]
Outer diameter of the spigot
ØD₁ [mm]
Outer diameter of the diffuser
m [kg]
Weight
Nomenclature
LWA [dB(A)]
A-weighted sound power level of air-regenerated noise
V [m³/h] and [l/s]
Volume flow rate
Δtz [K]
Supply air to room air temperature difference
Δpt [Pa]
Total differential pressure
All sound power levels are based on 1 pW.
Share page
Recommend this page
Recommend this page by sending a link by mail.
Share page
Thank you for your recommendation!
Your recommendation has been sent and should arrive shortly.
Contact
We are here for you
Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
Thank you for your message!
Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
We are here for you
Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
Thank you for your message!
Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265