TFP-TC-S_3d_02psd.png
TFP
TFP-TC-S_3d_03psd.png
TFP

Easy cleaning and validation

TFP_img_11psd.png
Construction with removable spigot

Construction with removable spigot

doc_graphic_000009.png
Tested to VDI 6022

Conforms to VDI 6022

TFP-TC-S_3d_02psd.png
TFP-TC-S_3d_03psd.png
TFP_img_11psd.png
doc_graphic_000009.png

TFP

For critical air cleanliness and very critical hygiene requirements, suitable for ceiling installation


 

Pharmaceutical clean room terminal filters as a final filter stage with Mini Pleat filter panels for the separation of suspended particles. Used in highly sensitive areas in pharmaceuticals, medicine, and biology

  • Mini Pleat filter panels with downstream fluid seals meet the highest hygiene requirements
  • Easy, time-saving, and secure filter change
  • Air terminal device is held in place by magnets and can be hinged down to facilitate cleaning and validation; filter change with patented turn clip
  • Newly designed supports for mounting in false ceilings
  • Robust, welded construction
  • Compact construction, suitable for low ceilings
  • Various diffuser face plates to ideally meet individual requirements
  • Horizontal or vertical connection
  • Removable spigot for installation into closed ceilings in case of horizontal connection
  • For air cleanliness classes 5 to 8 according to ISO 14644-1
  • Meets the hygiene requirements of VDI 6022

 

 

 


Updating order code
Save configuration
Calculate price
Updating technical data
  • Media
Specification text:
Updating specification text
Show complete text Hide complete text
Initialize order code

Allgemeine Informationen

Application

  • Pharmaceutical clean room terminal filter for ceiling installation as final filter stage and for air distribution in sensitive areas of the pharmaceutical industry
  • Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses or bacteria from the supply or extract air.


Variants

  • TC-S: Top entry circular spigot, top lateral suspension lugs
  • TC-FC: Top entry circular spigot, with supports for mounting in false ceilings
  • SC-S: Side entry circular spigot, top lateral suspension lugs
  • SC-FC: Side entry circular spigot, with supports for mounting in false ceilings
  • SCR-S: Side entry circular spigot, removable, top lateral suspension lug
  • SCR-FC: Side entry circular spigot, removable, with supports for mounting in false ceilings



Construction



  • Sheet steel, powder-coated, RAL 9010, pure white



Nominal sizes

  • 400, 500, 600, 625 [mm]



Attachments

  • FD: Ceiling swirl diffuser
  • TDF: Ceiling swirl diffuser
  • VDWF: Ceiling swirl diffuser


Useful additions

  • Mini Pleat filter panels (MFP)
  • Suitable filter elements to be ordered separately


Special characteristics

  • Compact construction
  • Flush ceiling installation
  • Removable spigot for installation into closed ceilings
  • Diffuser face plate can be hinged down
  • Filter change with patented turn clip
  • Supports for mounting in false ceilings



Construction features

  • Welded filter casing with sealing frame for fitting filter elements, with a seal on the downstream side
  • Mounted pressure measuring points for monitoring the operating differential pressure and internal measuring tube


Material and surfaces

  • Casing and diffuser face plate made of sheet steel, powder-coated RAL 9010, pure white



Commissioning

  • Fitting of filter elements with a fluid seal on the downstream side
  • Pressing of the filter element is performed using four patented turn clips
  • Air diffuser is hinged and held in place by magnets; no additional tools required


Standards and guidelines

  • Hygiene meets the requirements of VDI 6022, VDI 3803, DIN 1946 Part 4, ÖNORM H 6021 and ÖNORM H 6020, SWKI VA 104-01 and SWKI 99-3, and EN 16798



Maintenance

  • Diffuser face can be hinged down for easy disassembly and cleaning
  • Cleaning is possible with installed particulate filter (seal on downstream side)
  • Easy replacement of filter elements thanks to special frame profile, no additional fluid sealing frame

Technical information

Function, Specification text, Order code

  • Function
  • SPECIFICATION TEXT
  • ORDER CODE

Specification text


Pharmaceutical clean room terminal filter type TFP for ceiling installation as final filter stage and for air distribution in sensitive areas of the pharmaceutical industry.


Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply or extract air.


Welded filter casing with sealing frame for fixing the Mini Pleat filter panels, with a fluid seal on the downstream side.


With side entry or top entry spigot. Side entry spigot can be removed if desired.


Pressing the Mini Pleat filter panels is performed by four patented turn clips.


Casing with mounted pressure measurement points to monitor the operating differential pressure and with internal measuring tube.


Diffuser face plate made of sheet steel, powder-coated (RAL 9010), types FD and TDF; can be hinged down to facilitate disassembly and cleaning.


Leakage test for each casing.


 


Special features

  • Compact construction
  • Flush ceiling installation
  • Removable side spigot, for installation in closed ceilings
  • Diffuser face can be hinged down
  • Filter change with patented turn clip
  • Supports for mounting in suspended ceilings


Materials and surfaces

  • Casing and air terminal device made of sheet steel, powder-coated, RAL 9010, pure white


Constructions



  • Sheet steel, powder-coated, RAL 9010, pure white

 

 

 



TFPSC-SFD/600×198×330/CC
|||||||
1234567
1 Type
TFP
Pharmaceutical clean room terminal filters

2 Variant
TC-S
Top entry circular spigot, top lateral suspension lugs
TC-FC Top entry circular spigot, with supports for mounting in suspended ceilings
SC-S Side entry circular spigot, top lateral suspension lugs
SC-FC Side entry circular spigot, with supports for mounting in suspended ceilings
SCR-S Side entry circular spigot, removable, top lateral suspension lugs
SCR-FC Side entry circular spigot, removable, with supports for mounting in suspended ceilings

3 Air diffuser
FD, TDF, VDWF

4 Nominal size [mm]
400, 500, 600, 625

5 Spigot diameter ØD
[mm]
Specify diameter

6 Casing height [mm]
Specify casing height

7 Type of ceiling
No entry: Standard
CC Clip-in tile ceilingOrder example: TFP-SC-S-FD/600×198×330/CC
TypeTFP Pharmaceutical clean room terminal filter
VariantSide entry circular spigot, top lateral suspension lugs
Air diffuserFD
Nominal size [mm]600
Spigot diameter ØD [mm]198
Casing height [mm]330
Type of ceilingClip-in tile ceiling

Variants, Dimensions

  • Varianten
  • Dimensions

Product examples



 

 



,

Application

  • Pharmaceutical clean room terminal filter for ceiling installation as final filter stage and for air distribution in sensitive areas of the pharmaceutical industry
  • Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses, bacteria from the supply or extract air.

,

Application

  • Pharmazie-Reinraumdurchlass für Deckeneinbau als endständige Filterstufe und zur Luftführung in sensitiven Bereichen der pharmazeutischen Industrie
  • Aufnahme von Filterelementen zur Abscheidung von Schwebstoffen wie z. B. Aerosolen, toxischen Stäuben, Viren, Bakterien aus der Zu- und Abluft

,

Application

  • Pharmazie-Reinraumdurchlass für Deckeneinbau als endständige Filterstufe und zur Luftführung in sensitiven Bereichen der pharmazeutischen Industrie
  • Aufnahme von Filterelementen zur Abscheidung von Schwebstoffen wie z. B. Aerosolen, toxischen Stäuben, Viren, Bakterien aus der Zu- und Abluft

,

Application

  • Pharmazie-Reinraumdurchlass für Deckeneinbau als endständige Filterstufe und zur Luftführung in sensitiven Bereichen der pharmazeutischen Industrie
  • Aufnahme von Filterelementen zur Abscheidung von Schwebstoffen wie z. B. Aerosolen, toxischen Stäuben, Viren, Bakterien aus der Zu- und Abluft

FILTER CHANGE TFP SPECIAL CLAMP

Downloads

product information

certificates

operation manuals

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Contact

We are here for you

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265