PL18_img_04psd.png
Plenum box shorter than front rail, centrally positioned, with one horizontal connection pipe

PL_img_01psd.png
Spigot with optional damper blade and optional lip seal

Spigot with optional damper blade and optional lip seal

VSD35_gc_24psd.png
Alternating horizontal air discharge

Alternating horizontal air discharge

 

 

PL18_gc_26ai.png
Detachable diffuser face fixing

Detachable diffuser face fixing

 

 

PL18_img_11psd.png
PL18-2/.../B00/P1-RAL 9010, installation in continuous ceilings

PL18-2/.../B00/P1-RAL 9010, installation in continuous ceilings

 

 

PL18_img_04psd.png
PL_img_01psd.png
VSD35_gc_24psd.png
PL18_gc_26ai.png
PL18_img_11psd.png
Available online - configure now

PURELINE18  

Particularly slim diffuser face, available in many variants and with various air pattern options for many installation situations


Slot diffusers with 18 mm diffuser face (nominal width) and adjustable air control elements

  • Volume flow rate range 5 – 84 l/s or 17 – 302 m³/h
  • Individually adjustable air control elements for horizontal, angled or vertical air discharge
  • One-way or alternating air discharge allows for meeting local and project-specific requirements
  • Uniform air pattern reduces contamination of the ceiling due to induced room air
  • Air control elements have grooves that allow for precise positioning

 

Optional equipment and accessories

  • Attractive appearance due to extruded aluminium sections with anodised finish or powder coating
  • Diffuser face can be placed symmetrically or asymmetrically
  • Plenum box with lining
  • End plates, end angles, corner sections
  • Different looks due to choice of black, grey or white air control elements

 

 

 


Updating order code
Save configuration
Calculate price
Updating technical data
  • Media
Specification text:
Updating specification text
Show complete text Hide complete text
Initialize order code

Allgemeine Informationen

Application

  • Slot diffusers are used as supply air or extract air devices in comfort zones
  • Particularly unobtrusive diffusers due to their sleek design
  • Installation into suspended ceilings
  • For room heights up to 4 m (lower edge of suspended ceiling)
  • For suspended ceilings; suitable for restricted ceiling voids due to the low overall height of the plenum box
  • Suitable for continuous linear arrangement
  • Adjustable air control elements allow for horizontal, angled or vertical air discharge
  • Mixed flow system with one-way or alternating air discharge, can be adapted to the building structure
  • High induction results in a rapid reduction of the temperature difference and airflow velocity (supply air variant)
  • For variable and constant volume flows
  • For supply air to room air temperature differences from -10 to +10 K



Special features

  • Uniform air pattern reduces contamination of the ceiling due to induced room air
  • Horizontal, angled or vertical air discharge by means of manually adjustable air control elements
  • Comfortable indoor climate due to high induction and rapid reduction of temperature differences and airflow velocities
  • Attractive appearance thanks to anodised extruded aluminium sections (E6-C-0, natural colour) or powder coating (RAL CLASSIC colour)
  • Diffuser face has been optimised for maximum volume flow rate at low sound power levels
  • Suitable for continuous linear arrangement



Nominal sizes

  • FLN: 600, 700, 800, 900, 1000, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800, 1900, 2000 mm
  • Intermediate sizes of the diffuser face are also available (in increments of 1 mm)



Variants

PL18-... :

  • -*: 1 to 2 slots
  • -DF: only front rail with B00 profile and spring clip
  • -DS: only front rail with B00 profile and screw fixing


  • -PB: Plenum box only (for combination with DS)




  • -PF: Combination of diffuser face and plenum box with fixed connection




  • -SF: Combination of diffuser face and plenum box with detachable screw fixing


  • -CD: Overflow rail which can be integrated into a slotted belt. The front rail has openings at the back through which air can flow. The fixing of the overflow rail must be done on site. The supplied connectors are used only for positioning and aligning the overflow rail
  • -BD: Blind rail that can be integrated into a slotted band. The diffuser face is closed on the reverse side so that there is no air flow through the blind rail. The blind rail must be fixed on site. The supplied connectors are used only for positioning and aligning the overflow rail


  • -CS: Corner section




Position of the plenum box on the diffuser face, if the plenum box is shorter than the diffuser face





  • Central position of plenum box




  • Plenum box on the left (LE)




  • Plenum box on the right (RI)




Plenum box variant





  • Symmetrical plenum box with horizontal connection (HS)




  • Symmetrical plenum box with vertical connection (VS)




  • Asymmetrical plenum box with horizontal connection (HA)



Construction



Diffuser face finish





  • With anodised finish, E6-C-0, natural colour


  • P1: Powder-coated RAL 9010, pure white, GU50
  • P1: Powder-coated RAL 9006, white aluminium, GU30
  • P1: Powder-coated in any other RAL CLASSIC colour, GU70

Attachments

  • D: Damper blade for volume flow rate balancing




  • LS: Lip seal


  • L: inner lining


  • EP: 2 end plates




  • EA: 2 end angles


Single diffusers are factory fitted with end plates or end angles. Either end plates or end angles can be used for the front end for continuous linear arrangements.


Accessories
  • EP: 2 end plates


  • EA: 2 end angles


For slot diffusers as continuous linear arrangement, the end plates or end angles must be ordered separately and installed on site. 2 alignment plates for connecting the front rails to each other are supplied separately with each slot diffuser without a factory-fitted end piece.


Construction features



  • Spigot suitable for circular ducts to EN 1506 or EN 13180


  • 4 suspension lugs on plenum box for mounting by the customer


  • Manually adjustable air control elements with detent for defined adjustment of the air distribution


  • Spigot with groove for lip seal (only for lip seal version)


  • Diffuser face available in mm increments between 600 and1950 mm




  • Plenum boxes only available in nominal lengths




  • Extract air variant without air control elements (E)




  • If the diffuser face is longer than the plenum box, the rear side of the protruding diffuser face ends are covered.




  • Factory set for a particular air pattern, manually adjustable on site (by others)




  • Diffuser face fixing material for variants -SF and -DS supplied separately



Materials and surfaces

  • Diffuser face made from extruded aluminium section


  • Air control elements made of ABS plastic, UL 94, V-0, flame retardant




  • Plenum box made of galvanised sheet steel




  • End plates and end angles made of aluminium




  • Lip seal made of Evoprene


  • Lining made of mineral wool and closed-cell vinyl foam
  • Diffuser face with anodised finish, E6-C-0, natural colour
  • P1: powder-coated colour according to RAL CLASSIC


  • Air control elements similar to RAL 9005, black




  • G: Air control elements similar to RAL 9006, grey


  • W: Air control blades similar to RAL 9010, white

Mineral wool



  • Mineral wool faced with glass fibre fabric on the surfaces in contact with the air, abrasion-resistant up to 20 m/s




  • To EN 13501, fire rating class A1, non-combustible




  • RAL quality mark RAL-GZ 388




  • Non-hazardous to health thanks to being highly biosoluble in accordance with the Ordinance on Hazardous Substances and Note Q of the European Directive (EC) No. 1272/2008




  • Inert to fungal and bacterial growth



Standards and guidelines



  • Sound power level of the air-regenerated noise measured according to EN ISO 5135


  • Conforms to VDI 6022

Maintenance

  • Wartungsarm, da aufgrund der Konstruktion und der verwendeten Materialien keine Abnutzung erfolgt
  • Überprüfung und Reinigung nach VDI 6022

TECHNICAL INFORMATION

Function, Technical data, Quick sizing, Order code

  • Function
  • TECHNICAL DATA
  • QUICK SIZING
  • Order code

Slot diffusers direct the supply air from ventilation and air conditioning systems into the room, either horizontally, at an angle or vertically.

The resulting airflow induces high levels of room air, thereby rapidly reducing the airflow velocity and the temperature difference between supply air and indoor air.

The result is a mixed flow ventilation in comfort zones, with good overall room ventilation, creating only very little turbulence in the occupied zone.

Type PURELINE18 slot diffusers are factory fitted with manually adjustable air control elements.

The airflow direction can be adjusted to meet various local requirements.

Air discharge is one-way or alternating.

Heating operation with vertical flow is also possible, as is angled air discharge.

The supply air to room air temperature difference may range from –10 to +10 K.

A damper blade (optional) enables volume flow rate balancing for commissioning.

To give rooms an aesthetic, uniform look, Type PURELINE18 diffusers may also be used for extract air.


Nominal lengths600 – 2000 mm, in increments of 100 mm
No. of slots1 or 2

Minimum volume flow rate, with Δtz = -10 K

5 l/s or 17 m³/h
Maximum volume flow rate, with LWA ≅ 50 dB(A)84 l/s or 302 m³/h
Supply air to room air temperature difference-10 to +10 K

,


Quick sizing tables provide a good overview of the volume flow rates and corresponding sound power levels and differential pressures. Exact values for all parameters can be determined with our Easy Product Finder design program. Sizing up to nominal length 1500 mm includes one spigot; from length 1600 mm, two spigots are required.

PL18-1, supply air, alternating horizontal air discharge, sound power level and total differential pressure


D = 78

LN

qᵥ [l/s]qᵥ [m³/h]Damper blade position
45°90°
Δpₜ [Pa]LWA [dB(A)]Δpₜ [Pa]LWA [dB(A)]Δpₜ [Pa]LWA [dB(A)]
6005174<155<158<15
6001038152921293529
6001658344149408141
60022786249884914849
7006204<156<1510<15
7001242143022293929
7001863324149408941
70024855749884815949
8006234<156<1512<15
8001346143023294430
8001969314151409841
80026925449914817349
9007264<157<1514<15
9001450143125305030
90021753041544110941
90028995249954819049
10008294<158<1516<15
10001554143127305630
100022802941574111941
1000291055149994820649
11009325<159<1519<15
11001658143129306231
110024852942604113041
11003111150491044822449
1200103551610<152215
12001762143231316931
120025902942644114341
12003311750491094824349
1300113851711162516
13001866153234317732
13003412350491164826349
1400114161713162917
14001970153236318432
140027993042734116841
14003612850491214828149
1500124461814173318
15002074163340329332
1500291043142784118342
15003713451491294830449
160013474<156<1512<15
16002486123120303831
160035125254142418041
1600461644349724813849
170014494<157<1513<15
17002590123121314031
170036130254243418441
1700471704249744814449
180015524167<151415
18002694123222314331
180037135254244418941
1800491764149754815149
190015554168151516
19002798123222314631
190039140244246419341
1900511824149774815849
200016584178161616
200028101123223314832
200040144244247419741
2000521874049784816449

 



 



PL18-1, supply air, alternating horizontal air discharge, sound power level and total differential pressure

D = 98


LN

qᵥ [l/s]qᵥ [m³/h]Damper blade position
45°90°
Δpₜ [Pa]LWA [dB(A)]Δpₜ [Pa]LWA [dB(A)]Δpₜ [Pa]LWA [dB(A)]
6005173<154<155<15
6001038142616262226
6001658313837385038
6002278574667469146
7006203<154<156<15
7001242132716262326
7001863283835385138
7002485514663469146
8006233<154<157<15
8001346122716272427
8001969273835385438
8002692474661469446
9007264<155<157<15
9001450122816272627
9002175253835385738
9002899444661469946
10008294<155<158<15
10001554112817272828
10002280243835386038
1000291054146604510446
11009324<156<1510<15
11001658112817283028
11002485233836386438
1100311113946614510946
120010354<156<1511<15
12001762112918283328
12002590233937386838
1200331173846624511546
130011384<156<1512<15
13001866112919283629
13002695223938387338
1300341233746644512346
140011414<157<1513<15
14001970112920283929
14002799223939387738
1400361283646654512946
150012444158<1515<15
15002074113021294229
150029104223941388339
1500371343646674513746
160013473<154<157<15
16002486112814282128
160035125223929384438
160046164374649467546
170014493<155<157<15
17002590102814282228
170036130213928384538
170047170364648467746
180015524<155<157<15
18002694102914282328
180037135213929384638
180049176354648467946
190015554<155<158<15
19002798102914282429
190039140203929384838
190051182344648468146
200016584<155<158<15
200028101102914282429
200040144203929384938
200052187334648458246


 



PL18-2, supply air, alternating horizontal air discharge, sound power level and total differential pressure

D = 98


LN

qᵥ [l/s]qᵥ [m³/h]Damper blade position
45°90°
Δpₜ [Pa]LWA [dB(A)]Δpₜ [Pa]LWA [dB(A)]Δpₜ [Pa]LWA [dB(A)]
60010354<156<1511<15
6001967133021283729
6002798284146398140
600361304949794714148
70011414<157<1513<15
7002174133123294330
70030108274148399040
800391414649824715548
80013475169<1516<15
8002381133225294931
800321162642513910040
900421514449854716948
900155251810152016
9002589143228305631
900351252642543911141
1000451614449904618548
1000165861912162418
10002795143330306432
1000371332742583912341
1200471704349954620148
1100186462013182819
110028102143433317132
1100391402742623913441
1300197072215193320
120030109153436317933
1200411472743664014641
12005218643491054623248
1300217672317203821
130032115163540318833
1300431552843714015841
13005419444491124624948
1400238182420214422
140034121173543329733
1400451612943754017041
14005620145491174626548
1500248782522225023
1500351281735473210634
1500471683043804018342
15005820846491234628148
160026935199171618
160042152123322314332
160059211224242408341
1600752703649684713548
170027995209181819
170044159123323314632
170061218224243408741
1700772783549704614048
18002910552110182020
180046165123424314932
180063226224245409241
1800802873549724614748
19003111152211192220
190048172123425315233
190065234224346409641
1900822953549744615348
20003211662212202421
200050178123426325633
2000672402243484010041
2000843023449754615948


 



PL18-2, supply air, alternating horizontal air discharge, sound power level and total differential pressure

D = 123


LN

qᵥ [l/s]qᵥ [m³/h]Damper blade position
45°90°
Δpₜ [Pa]LWA [dB(A)]Δpₜ [Pa]LWA [dB(A)]Δpₜ [Pa]LWA [dB(A)]
60010354<154<156<15
6001967112715262126
6002798243831364637
60036130424554447945
70011414<155<157<15
7002174112715262327
70030108223831364837
80039141384552448244
80013474<155<159<15
8002381112815262527
80032116213831365137
90042151354551438544
90015524<156<1510<15
9002589102816272827
90035125203831365437
100045161334552439044
100016584157<1512<15
10002795102917273028
100037133193832365837
120047170314552439544
110018644167<151315
110028102102918273328
110039140193833366237
130019705188151516
120030109103019283629
120041147183834366637
1200521862945544310544
130021765199161717
130032115103020283929
130043155183936367137
1300541942945564311144
1400238152010172018
140034121113121284330
140045161183937367537
1400562012845574211744
1500248752111182219
150035128113122294630
150047168183939368038
1500582082845594212344
160026934155<159<15
16004215292913282228
160059211173825374237
160075270284541446844
170027994166<15915
17004415992914282328
170061218173825374337
170077278274541436944
1800291054176151016
18004616593014282429
180063226173826374537
180080287264541437244
1900311114186161117
19004817293014282529
190065234163926374638
190082295264541437344
2000321164187161217
20005017893015282629
200067240163926374838
200084302254541437544

PL181SSFHS/1200 × 1000 × 98/2D LSL RI/AS/B00/EA/P1 - RAL 9016/W
| | | | | | | | | | | | | | | |
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 Type
PL18
Slot diffuser PURELINE18

2 No. of slots
1, 2


3 System
S
Supply air
E Extract air (without air control elements as standard)
E1 Extract air (with air control elements)

4 Variant
DF
Diffuser face with spring clip (only together with B00)
DS Diffuser face with fixing screws (only together with B00)
CD Air transfer section
BD Non-active diffuser
PB Plenum box only
PF Diffuser face fixed to the plenum box, non-detachable
SF Diffuser face fixed to the plenum box, detachable (only together with B00)

5 Plenum box variant
HS
Symmetrical, with horizontal spigot
VS Symmetrical, with vertical spigot
HA Asymmetrical, with horizontal spigot

6 Nominal size [mm]
Diffuser face length × plenum box length × spigot diameter

Diffuser face length
600 – 2000

Plenum box length
600 – 2000 (in increments of 100 mm)

Spigot diameter
78 (with 1 slot)
98 (with 1 or 2 slots)
123 (with 2 slots)

7 No. of spigots
1
(up to plenum box length 1200 mm)
2 (from plenum box length 900 mm)

8 Damper blade for volume flow rate balancing
No entry: without damper blade
D With damper blade

9 Lip seal
No entry: without lip seal
LS With lip seal

10 Lining
No entry: without lining
L With lining

11 Position of plenum box
No entry: centre
LE Left side
Rl Right side

12 Air pattern
No entry: alternating horizontal
AS Alternating angled
HL Horizontal left
HR Horizontal right
V Vertical

13 Extended border – diffuser face
No entry: without extended border
B00 With extended border

14 End pieces
No entry: without end pieces
EP End plate
EA End angle
To be ordered separately for continuous linear runs

15 Surface
No entry: anodised, E6-C-0 (no colour)
P1 Powder-coated, specify RAL CLASSIC colour

Gloss level
RAL 9010 GU50
RAL 9006 GU30
All other RAL colours GU70

16 Colour of air control elements
No entry: similar to RAL 9005 (jet black)
W Similar to RAL 9010 (pure white)
G Similar to RAL 9006 (white aluminium)Order example: PL18-1-S-PF-HS/1200×1200×98/1
TypePURELINE18
Number of slots1
SystemSupply air
VariantDiffuser face fixed to the plenum box, non-detachable
Plenum box variantSymmetrical plenum box with side entry spigot
Nominal sizeDiffuser face 1200 mm, plenum box 1200 mm, spigot diameter 98 mm
No. of spigots1
Damper blade for volume flow rate balancingWithout
Lip sealWithout
LiningWithout
Position of plenum boxCentre
Air patternAlternating horizontal
Extended borderWithout
End piecesWithout
SurfaceAnodised, E6-C-0, natural colour
Colour of air control elementsBlack
,
PL181CS/100 × 100 × 90/B00/P1 - RAL 9016/W
| | | | | | | |
1 2 3 4 5 6 7 8
1 Type
PL18
Slot diffuser PURELINE18

2 No. of slots
1, 2

3 System
S
Supply air
E Extract air (without air control elements as standard)
E1 Extract air (with air control elements)

4 Variant
CS
Corner section

5 Dimensions
Leg length E [mm]
100 – 300 (in increments of 1 mm)

Leg length F [mm]
100 – 300 (in increments of 1 mm)

Angle [°]
45 – 175 (in increments of 1 degree)

6 Extended border – diffuser face
No entry: without extended border
B00 With extended border

7 Surface
No entry: anodised, E6-C-0 (no colour)
P1 Powder-coated, specify RAL CLASSIC colour

Gloss level
RAL 9010 GU50
RAL 9006 GU30
All other RAL colours GU70

8 Colour of air control elements
No entry: similar to RAL 9005 (jet black)
W Similar to RAL 9010 (pure white)
G Similar to RAL 9006 (white aluminium),
PL18EA/2B00/P1 - RAL 9016
| | | | |
1 2 3 4 5
1 Type
PL18
Slot diffuser PURELINE18

2 Variant
EP 1 pair of end plates
EA 1 pair of end angles

3 No. of slots
1, 2

4 Extended border
No entry: without extended border
B00 With extended border

5 Surface
No entry: anodised, E6-C-0 (no colour)
P1 Powder-coated, specify RAL CLASSIC colour

Gloss level
RAL 9010 GU50
RAL 9006 GU30
All other RAL colours GU70

Variants

  • Variants

Application

  • Schlitzdurchlässe als Zuluft- oder Abluftdurchlass für Komfortbereiche
  • Durch das schmale Erscheinungsbild entsteht ein besonders unauffälliger Luftdurchlass
  • Einbau in abgehängte Decken
  • Für Räume bis ca. 4 m Höhe (Unterkante Fertigdecke)
  • Für abgehängte Decken, auch bei niedrigem Zwischenraum, aufgrund der geringen Höhe des Anschlusskastens
  • Optisch durchlaufende Bandverlegung möglich
  • Durch verstellbare Luftleitelemente für horizontale, schräge oder vertikale Luftführung
  • Mischlüftungssystem mit einseitiger oder wechselseitiger Luftführung vor Ort an die baulichen Gegebenheiten anpassbar
  • Hohe Induktion bewirkt schnellen Abbau der Temperaturdifferenz und der Luftgeschwindigkeit (bei Zuluft)
  • Für konstante und variable Volumenströme
  • Für Zulufttemperaturdifferenzen von -10 – +10 K

Application

  • Schlitzdurchlässe als Zuluft- oder Abluftdurchlass für Komfortbereiche
  • Durch das schmale Erscheinungsbild entsteht ein besonders unauffälliger Luftdurchlass
  • Einbau in abgehängte Decken
  • Für Räume bis ca. 4 m Höhe (Unterkante Fertigdecke)
  • Für abgehängte Decken, auch bei niedrigem Zwischenraum, aufgrund der geringen Höhe des Anschlusskastens
  • Optisch durchlaufende Bandverlegung möglich
  • Durch verstellbare Luftleitelemente für horizontale, schräge oder vertikale Luftführung
  • Mischlüftungssystem mit einseitiger oder wechselseitiger Luftführung vor Ort an die baulichen Gegebenheiten anpassbar
  • Hohe Induktion bewirkt schnellen Abbau der Temperaturdifferenz und der Luftgeschwindigkeit (bei Zuluft)
  • Für konstante und variable Volumenströme
  • Für Zulufttemperaturdifferenzen von -10 – +10 K

Application

  • Schlitzdurchlässe als Zuluft- oder Abluftdurchlass für Komfortbereiche
  • Durch das schmale Erscheinungsbild entsteht ein besonders unauffälliger Luftdurchlass
  • Einbau in abgehängte Decken
  • Für Räume bis ca. 4 m Höhe (Unterkante Fertigdecke)
  • Für abgehängte Decken, auch bei niedrigem Zwischenraum, aufgrund der geringen Höhe des Anschlusskastens
  • Optisch durchlaufende Bandverlegung möglich
  • Durch verstellbare Luftleitelemente für horizontale, schräge oder vertikale Luftführung
  • Mischlüftungssystem mit einseitiger oder wechselseitiger Luftführung vor Ort an die baulichen Gegebenheiten anpassbar
  • Hohe Induktion bewirkt schnellen Abbau der Temperaturdifferenz und der Luftgeschwindigkeit (bei Zuluft)
  • Für konstante und variable Volumenströme
  • Für Zulufttemperaturdifferenzen von -10 – +10 K

Downloads

product information

certificates

operation manuals

production {"X-Frame-Options"=>"SAMEORIGIN", "X-XSS-Protection"=>"1; mode=block", "X-Content-Type-Options"=>"nosniff", "X-Download-Options"=>"noopen", "X-Permitted-Cross-Domain-Policies"=>"none", "Referrer-Policy"=>"strict-origin-when-cross-origin", "Strict-Transport-Security"=>"max-age=31536000; includeSubDomains", "Content-Type"=>"text/html; charset=utf-8"}

Share page

Recommend this page

Recommend this page by sending a link by mail.

Fields marked with an (*) are required fields.

Share page

Thank you for your recommendation!

Your recommendation has been sent and should arrive shortly.

Contact

We are here for you

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Contact

We are here for you

Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265

Attachment (max. 10MB)

Fields marked with an (*) are required fields.

Contact

Thank you for your message!

Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265