Various design options with black, grey and white air control blades
Application
Special characteristics
Nominal sizes
Nominal length LN:
Spigot diameter ØD
Neck length
Variants
Diffuser face
Number of slots
System
Construction
Surface diffuser faceAttachments
Spigot
Splitter
End pieces
Construction features
Accessories
End pieces
Material and surfaces
Standards and guidelines
Maintenance
Wall diffusers allow the supply air of room air conditioning systems to flow with ceiling influence or directly into the room. The flow takes place with a high induction of the room air. This quickly reduces the air velocity and the temperature difference between supply air and room air. The result is a mixed ventilation system for comfort areas with good room air circulation and low turbulence in the occupied zone.
The wall diffusers can be combined with PURELINE 18, PURELINE35 or PURELINE50 range front rails. These have factory-set air control blades that can be manually adjusted on site. The airflow direction can be adjusted to meet various local requirements.
The supply air to room air temperature difference may range from –10 to +10 K.
A spigot can be optionally integrated in the plenum box to increase the passage attenuation and reduce the sound transmission into neighbouring rooms.
Damper blades (optional) in the spigot enable the volume flow rate to be balanced during commissioning. The damper blade is adjusted via cable pulls and can also be adjusted when the diffuser face is mounted.
For an architecturally uniform design, the wall diffusers are used as extract air diffusers or as supply air/extract air combinations.
CHS-18
Nominal length | 500 – 1200 mm (in increments of 100 mm) |
Number of slots | 1 or 2 |
minimum volume flow at Δtz = -10 K | 4 l/s or 13 m³/h |
maximum volume flow at LWA 50 dB (A) | 83 l/s or 300 m³/h |
Supply air to room air temperature difference | -10 – +10 K |
CHS-35
Nominal length | 450 – 1200 mm (in increments of 150 mm) |
Number of slots | 1, 2, 3 or 4 |
minimum volume flow at Δtz = -10 K | 5 l/s or 19 m³/h |
maximum volume flow at LWA 50 dB (A) | 160 l/s or 575 m³/h |
Supply air to room air temperature difference | -10 – +10 K |
CHS-50
Nominal length | 450 – 1200 mm (in increments of 150 mm) |
Number of slots | 1 or 2 |
minimum volume flow at Δtz = -10 K | 8 l/s or 27 m³/h |
maximum volume flow at LWA 50 dB (A) | 153 l/s or 550 m³/h |
Supply air to room air temperature difference | -10 – +10 K |
Specification text
Wall diffusers as supply air or extract air diffusers or supply air/extract air combinations for ventilating rooms in ventilation and air conditioning systems. Consisting of a plenum box with spigot for connection to the on-site duct system and the front rail. The air into the room is provided by air control blades integrated in the front rails. These air control blades are manually adjustable and enable airflow with ceiling influence or direct airflow into the room. Optional splitter for improved cross-talk sound attenuation.
Material
Surfaces
Nominal size
Length [mm]Standards and guidelines
Variants
Accessories
Equivalence criteria
Make of the tender
Type
CHS | – | 35 | – | 2 | – | SE | / | 1200 × 123 × 125 | / | 1 | / | D | / | LS | / | CT | / | NO | / | HR | / | F | / | P1 - RAL 9016 | / | W |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |||||||||||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 |
Order example: CHS-35-2-SE/1200×123×125/2/D/LS/CT/NO/HR/F/P1-RAL9016/W
Type | CHS |
Front rail | PURELINE35 |
Number of slots | 2 |
System | Supply and extract air combination |
Dimensions [mm] | Nominal length 1200, spigot diameter 123, neck length 125 |
Number of spigots | 2 |
Damper blade for volume flow rate balancing | with damper blade |
Lip seal | with lip seal |
Splitters | with splitters |
End pieces | without end angles |
Settings airflow | Airflow with ceiling effect |
Fixing | with bracket for wall mounting |
Surface front rail | powder-coated, RAL 9016 (traffic white) |
Colour of air control blades | similar to RAL 9010 (pure white) |
Application
Application
Installation and commissioning
The schematic diagrams are provided to illustrate installation details.
Share page
Recommend this page
Recommend this page by sending a link by mail.
Share page
Thank you for your recommendation!
Your recommendation has been sent and should arrive shortly.
Contact
We are here for you
Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
Thank you for your message!
Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
We are here for you
Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
Thank you for your message!
Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265