Application
Special characteristics
Nominal sizes
Variants
Connection
Parts and characteristics
Attachments
Accessories
Construction features
Materials and surfaces
Standards and guidelines
Maintenance
Functional description
Ceiling swirl diffusers in air conditioning systems create a swirl to supply air to rooms. The resulting airflow induces high levels of room air, thereby rapidly reducing the airflow velocity and the temperature difference between supply air and room air. Ceiling swirl diffusers allow for large volume flow rates. The result is a mixed flow ventilation in comfort zones, with good overall room ventilation, creating only very little turbulence in the occupied zone.
Type TDV ceiling swirl diffusers have adjustable air control blades. The air pattern can be adjusted to meet different local requirements. Horizontal air discharge is one-way, two-way or omni directional. Vertical air discharge is possible but only for heating. The supply air to room air temperature difference may range from –12 to +10 K.
A damper blade (optional) simplifies volume flow rate balancing for commissioning. Pressure tap and cord-operated damper blade (optional) allow for volume flow rate balancing with the diffuser face in place.
To give rooms an aesthetic, uniform look, Type TDV diffusers may also be used for extract air. Air control blades are not required for extract air applications.
Nominal sizes | 300, 400, 500, 600, 625 mm |
Minimum volume flow rate, with ΔtZ = –6 K | 11 – 47 l/s or 40 – 169 m³/h |
Maximum volume flow rate, with LWA ≅ 50 dB(A) | 95 – 315 l/s or 342 – 1134 m³/h |
Supply air to room air temperature difference | –12 to +10 K |
Quick sizing tables provide a good overview of the volume flow rates and corresponding sound power levels and differential pressures.
The minimum volume flow rates apply to a supply air to room air temperature difference of –6 K.
The maximum volume flow rates apply to a sound power level of approx. 50 dB (A) with damper blade position 0°.
Exact values for all parameters can be determined with our Easy Product Finder design programme.
TDV-SA-Q-Z-H (supply air), sound power level and total differential pressure
300 | 11 | 40 | 1 | <15 | 1 | <15 | 2 | <15 |
300 | 40 | 144 | 11 | 25 | 14 | 27 | 32 | 25 |
300 | 65 | 234 | 28 | 37 | 37 | 37 | 83 | 38 |
300 | 95 | 342 | 60 | 50 | 79 | 48 | 179 | 52 |
400 | 20 | 72 | 1 | <15 | 1 | <15 | 3 | <15 |
400 | 60 | 216 | 10 | 26 | 12 | 18 | 28 | 27 |
400 | 100 | 360 | 26 | 39 | 35 | 36 | 79 | 39 |
400 | 140 | 504 | 52 | 50 | 68 | 49 | 154 | 49 |
500 | 30 | 108 | 1 | <15 | 2 | <15 | 6 | <15 |
500 | 80 | 288 | 11 | 22 | 16 | 21 | 46 | 26 |
500 | 135 | 486 | 30 | 38 | 46 | 38 | 130 | 43 |
500 | 190 | 684 | 59 | 50 | 91 | 51 | 257 | 55 |
600, 625 | 47 | 169 | 2 | <15 | 2 | <15 | 6 | <15 |
600, 625 | 125 | 450 | 12 | 22 | 15 | 22 | 44 | 27 |
600, 625 | 200 | 720 | 30 | 38 | 39 | 37 | 112 | 43 |
600, 625 | 275 | 990 | 57 | 50 | 74 | 49 | 212 | 55 |
TDV-SA-R-Z-H (supply air), sound power level and total differential pressure
300 | 11 | 40 | 1 | <15 | 1 | <15 | 2 | <15 |
300 | 40 | 144 | 10 | 25 | 14 | 24 | 32 | 23 |
300 | 70 | 252 | 31 | 35 | 43 | 36 | 97 | 38 |
300 | 111 | 398 | 78 | 50 | 108 | 50 | 243 | 54 |
400 | 20 | 72 | 1 | <15 | 1 | <15 | 3 | <15 |
400 | 65 | 234 | 11 | 25 | 14 | 25 | 34 | 25 |
400 | 115 | 414 | 34 | 39 | 45 | 39 | 105 | 41 |
400 | 155 | 558 | 62 | 50 | 82 | 48 | 191 | 51 |
500 | 30 | 108 | 1 | <15 | 2 | <15 | 6 | <15 |
500 | 90 | 324 | 13 | 22 | 20 | 23 | 56 | 28 |
500 | 155 | 558 | 39 | 38 | 59 | 40 | 165 | 45 |
500 | 215 | 774 | 75 | 50 | 114 | 52 | 318 | 57 |
600, 625 | 47 | 169 | 2 | <15 | 2 | <15 | 6 | <15 |
600, 625 | 130 | 468 | 13 | 21 | 19 | 22 | 47 | 30 |
600, 625 | 215 | 774 | 35 | 37 | 51 | 38 | 130 | 45 |
600, 625 | 295 | 1062 | 66 | 50 | 96 | 50 | 244 | 57 |
TDV-SA-*-Z-V (supply air), sound power level and total differential pressure
300 | 11 | 40 | 1 | <15 | 1 | <15 | 2 | <15 |
300 | 30 | 108 | 6 | 17 | 8 | 19 | 17 | 18 |
300 | 65 | 234 | 29 | 37 | 36 | 38 | 82 | 38 |
300 | 95 | 342 | 63 | 50 | 77 | 51 | 174 | 52 |
400 | 20 | 72 | 1 | <15 | 1 | <15 | 3 | <15 |
400 | 60 | 216 | 9 | 21 | 12 | 23 | 29 | 22 |
400 | 110 | 396 | 31 | 39 | 40 | 39 | 96 | 42 |
400 | 150 | 540 | 58 | 50 | 73 | 51 | 179 | 54 |
500 | 30 | 108 | 1 | <15 | 2 | <15 | 6 | <15 |
500 | 85 | 306 | 11 | 20 | 18 | 23 | 49 | 29 |
500 | 140 | 504 | 30 | 38 | 49 | 42 | 133 | 46 |
500 | 195 | 702 | 59 | 50 | 94 | 56 | 258 | 58 |
600, 625 | 47 | 169 | 2 | <15 | 3 | <15 | 7 | <15 |
600, 625 | 120 | 432 | 12 | 23 | 17 | 25 | 42 | 33 |
600, 625 | 190 | 684 | 29 | 38 | 42 | 42 | 106 | 48 |
600, 625 | 260 | 936 | 55 | 50 | 79 | 55 | 198 | 60 |
Ceiling swirl diffusers with square or circular diffuser face. Supply air and extract air variants for comfort zones. Diffuser face with individually manually adjustable air control blades for horizontal swirling supply air discharge creating high induction levels. For installation into all types of suspended ceilings.
Ready-to-install component which consists of the diffuser face with radially arranged, individually adjustable black or white air control blades, and of a plenum box, equalising element (only supply air variants), side entry or top entry spigot, and suspension holes or suspension lugs.
The diffuser face is fixed to the cross bar with a central screw, concealed by a decorative cap.
Spigot suitable for ducts to EN 1506 or EN 13180.
Sound power level of the air-regenerated noise measured according to EN ISO 5135.
Special characteristics
Materials and surfaces
Technical data
Sizing data
Air-regenerated noise
Order example: TDV-SA–Q–Z–H–MN–L/600/P1–RAL 9016
Construction style | Square |
System | Supply air |
Connection | Horizontal |
Damper blade for volume flow rate balancing | With cords and pressure tap |
Accessories | Lip seal |
Nominal size | 600 |
Colour of air control blades | Black |
Exposed surface | RAL 9016, traffic white, gloss level 70 % |
TDV-SA-Q-*-H
Designed for high comfort
Together with renowned designers and architects we have developed ceiling, wall, staircase and floor diffusers and grilles that are not only aesthetic design elements, but also meet demanding ventilation and acoustic requirements.
Variant
Nominal sizes
Parts and characteristics
Construction features
TDV-SA-Q-*-V
Designed for high comfort
Together with renowned designers and architects we have developed ceiling, wall, staircase and floor diffusers and grilles that are not only aesthetic design elements, but also meet demanding ventilation and acoustic requirements.
Variant
Nominal sizes
Parts and characteristics
Construction features
TDV-SA-R-*-H
Designed for high comfort
Together with renowned designers and architects we have developed ceiling, wall, staircase and floor diffusers and grilles that are not only aesthetic design elements, but also meet demanding ventilation and acoustic requirements.
Variant
Nominal sizes
Parts and characteristics
Construction features
TDV-SA-R-*-V
Designed for high comfort
Together with renowned designers and architects we have developed ceiling, wall, staircase and floor diffusers and grilles that are not only aesthetic design elements, but also meet demanding ventilation and acoustic requirements.
Variant
Nominal sizes
Parts and characteristics
Construction features
TDV-SA-Q-*-H
mm | mm | mm | mm | mm | mm | mm | kg | ||
Weights apply to the supply air variant
TDV-SA-Q-*-V
mm | mm | mm | mm | mm | mm | kg | |
Weights apply to the supply air variant
TDV-SA-R-*-H
mm | mm | mm | mm | mm | mm | mm | mm | mm | kg | ||
Weights apply to the supply air variant
TDV-SA-R-*-V
mm | mm | mm | mm | mm | mm | kg | |
Weights apply to the supply air variant
Installation and commissioning
These are only schematic diagrams to illustrate installation details.
Volume flow rate balancing
When several diffusers are connected to just one volume flow controller, it may be necessary to balance the volume flow rates.
Volume flow rate measurement
Ceiling diffusers with universal plenum box, damper blade and pressure tap (variant -MN) allow for volume flow rate balancing even with the diffuser face in place.
A characteristic is included with each AK-Uni plenum box.
Principal dimensions
ØD [mm]
Outer diameter of the spigot
ØD₁ [mm]
Outer diameter of a circular diffuser face
ØD₂ [mm]
Diameter of a circular diffuser face style
ØD₃ [mm]
Diameter of a circular plenum box
□Q₁ [mm]
Outer diameter of a square diffuser face
□Q₂ [mm]
Dimensions of a square diffuser face style
□Q₃ [mm]
Dimensions of a square plenum box
H₁ [mm]
Distance (height) from the lower edge of the suspended ceiling to the lower edge of the diffuser face
H₂ [mm]
Height of a ceiling diffuser, from the lower edge of the suspended ceiling to the upper edge of the spigot
H₃ [mm]
Height of a ceiling diffuser with plenum box, from the lower edge of the suspended ceiling to the upper edge of the plenum box or of the spigot
A [mm]
Position of the spigot, defined by the distance of the spigot centre line to the lower edge of the suspended ceiling
C [mm]
Length of the spigot
m [kg]
Weight
Nomenclature
LWA [dB(A)]
A-weighted sound power level of air-regenerated noise
V [m³/h] and [l/s]
Volume flow rate
Δtz [K]
Supply air to room air temperature difference, i.e. supply air temperature minus room temperature
Δpt [Pa]
Total differential pressure
Aeff [m²]
Effective air discharge area
All sound power levels are based on 1 pW.
Share page
Recommend this page
Recommend this page by sending a link by mail.
Share page
Thank you for your recommendation!
Your recommendation has been sent and should arrive shortly.
Contact
We are here for you
Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
Thank you for your message!
Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
We are here for you
Please specify your message and type of request
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265
Contact
Thank you for your message!
Your message is send and will be processed shortly.
Our department for Service-Requests will contact you asap.
For general question regarding products or services you can also call:
Tel.: +49 (0)2845 / 202-0 | Fax: +49 (0)2845/202-265